G.V. DVIRNY, K.V. KONDRATYEV, V.N. SERGEEVICH, A.F. SHISHKINA
The article describes the development of a remote calibration module (MDC) and outlines
the results of its 3D modeling. The module to be developed will be used to calibrate the drawbar, which is part of the automated workplace of fi ring acceptance tests of plasma jet engines. Since jet engines operate under specifi c conditions, special requirements are imposed on all workstation modules, in particular minimum dimensions and compactness. The remote calibration module will be based on a piezoceramic bimorph. The principle of functioning of the piezoceramic bimorph is based on its bending relative to the average position under the infl uence of an alternating voltage. The developed model MDK allows you to remotely lead a step-by-step calibration and meets the conditions imposed by the technical task for this module.
Key words:remote calibration module design, vacuum pezoaktuator, piezoceramic bimorph, converter efforts.
Contacts: E-mail: Kondratyev-37@mail.ru
Pp. 62-67. |
|
|
|
Last news:
Выставки по автоматизации и электронике «ПТА-Урал 2018» и «Электроника-Урал 2018» состоятся в Екатеринбурге Открыта электронная регистрация на выставку Дефектоскопия / NDT St. Petersburg Открыта регистрация на 9-ю Международную научно-практическую конференцию «Строительство и ремонт скважин — 2018» ExpoElectronica и ElectronTechExpo 2018: рост площади экспозиции на 19% и новые формы контент-программы Тематика и состав экспозиции РЭП на выставке "ChipEXPO - 2018" |