Test of the thyristor inverter with frequency doubling by mathematical modeling |
V.I. Diaghilev, V.V. Shipitsyn, A.V. Diaghilev, N.V. Kulagin
The article presents the results of mathematical modeling on computers thyristor inverter with frequency doubling and recuperation of the excess energy of the handling circuit when mode of work changes. It is an important factor to ensure the reliable operation of electrical installations. This model provides a method of calculation and choice of parameters of high-power and high-frequency thyristor inverters. Keywords: Thyristor inverter, frequency doubling, recovery of excess energy.
E-mail: Nikita.Kulagin@ihep.ru |
|
|
|
Last news:
Выставки по автоматизации и электронике «ПТА-Урал 2018» и «Электроника-Урал 2018» состоятся в Екатеринбурге Открыта электронная регистрация на выставку Дефектоскопия / NDT St. Petersburg Открыта регистрация на 9-ю Международную научно-практическую конференцию «Строительство и ремонт скважин — 2018» ExpoElectronica и ElectronTechExpo 2018: рост площади экспозиции на 19% и новые формы контент-программы Тематика и состав экспозиции РЭП на выставке "ChipEXPO - 2018" |